VOLTAS Fault Code
A1- Indoor ambient temperature sensor failure.
A2 - Temperature sensor about middle position of evaporator
failure.
A3 - Indoor coil pipe inlet temperature sensor failure.
A4 - Indoor coil pipe outlet temperature sensor failure.
A5 - Indoor water
pump failure .
A6 - Failure of indoor PG fan.
H1 - HPSa fault / Fluctuation of voltage ( application to
some models ) .
H5 - Refrigerant shortage protection.
HJ - Missing phase or phase sequence errors in three - phase
power supply .
HF - Low oil temperature protection.
C1 - Environment temperature sensor Tao fault.
C2 - Defrost temperature sensor Tdef fault.
C3 - Discharge temperature of inverter compressor 1 failure.
C4 - Discharge temperature of inverter compressor 2 failure.
C6 - Suction temperature of compressor failure.
C9 - Heat exchanger inlet Tcol fault.
CJ - Oil temperature Toila fault.
CC - Liquid outlet of plate heat exchanger temperature
sensor fault .
CE - Gas inlet of plate heat exchanger temperature sensor
fault .
CF - Gas outlet of plate heat exchanger temperature sensor
fault.
J1 - The communication between ODU and ODU failed.
J2 - Communication error between outdoor and indoor unit .
J3 - The communication between PCB and INV module failure.
J4 - The communication between main PCB and DC fan motor
drive module failure.
J5 - Outdoor unit parameter setting incorrect.
J7 - Outdoor unit main control PCB ERROM module failure.
A8 - Indoor unit EEPROM module failure .
A9 - The communication between indoor unit and outdoor unit
failed.
AA - The communication between indoor unit and wire
controller failed.
AC - Two or more indoor unit central control system address
repeated.
AE - Operation mode
conflict.
AH - Two or more indoor unit refrigerant system address
repeated.
AJ - Indoor unit total capacity exceeded.
JJ - Indoor unit total capacity exceeding.
E1 - The four - valve is in fault.
E3 - DC inverter compressor 1 discharge temperature " Tda too high shutdown protection .
E4 - DC inverter compressor 2 discharge temperature "
Tda " too high shutdown protection.
E9 - Drive refrigerant cooling pipe low temperature
protection.
F1 - High pressure sensor " Pd " failure.
F3 - High pressure sensor " Pd " protection .
F4 - Low pressure sensor " Ps " failure .
F6 - Low pressure sensor " Ps " protection.
F8 - Compression ratio too high protection .
F9 - Compression ratio too low protection .
FH - DC inverter discharge temperature " Tda too low
shutdown protection ..
31 - IPM module protection.
32 - Compressor 1 Module hardware protection.
33 - Compressor I Module software protection .
34 - Compressor I unconnected .
35 - Compressor I phase current overload protection.
36 - Compressor 1 DC bus voltage over - voltage or under -
voltage failure.
37 Compressor I temperature sensor of drive module heat fins
failure.
38 - Compressor I drive module high temperature limit
frequency failure.
39 - Compressor I drive module high Temp . shutdown
protection .
3A - DC fan motor I drive module protection.
3H - DC fan motor I drive module start failure of Running
out of step.
3C - DC fan motor 1 drive module overcurrent protection of
overcurrent sensor failure .
3J - DC fan motor 1 drive module over - voltage or under -
voltage protection .
3E - Compressor I input current protection.
3F - Compressor I drive module PFC protection.
41 - DC fan motor I drive module IPM alarm.
47 - Indoor unit loss failure.
49 - DC fan motor 2 drive module IPM alarm .
51- Compression2 drive module IPM protection .
52 - Compressor 2 Module hardware protection.
53 - Compressor 2 Module software protection .
54 - Compressor 2 unconnected.
55 - Compressor 2 phase current overload protection.
56 - Compressor 2 DC bus voltage over - voltage of under -
voltage failure.
57 - Compressor 2 temperature sensor of drive module heat
fins failure.
58 - Compressor 2 drive module high temperature limit
frequency failure .
59 - Compressor 2 drive module high Temp , shutdown
protection.
5A - DC fan motor 2drive module protection.
5H - DC fan motor 2 drive module start failure or a Running
out of step .
5C - DC fan motor 2 drive module over current protection of
over current sensor failure.
5J - DC fan motor 2 drive module over - voltage or under -
voltage protection.
5E - Compressor 2 input current protection.
5F - Compressor 2 drive module PFC protection.
10 Comments
How to fix AH ERROR
ReplyDeleteH9
DeleteHow to fix 33 error
ReplyDelete1hd ka kya matleb hota he
ReplyDeleteVoltas vxv me HJ error code AA Raha hi
ReplyDelete88 error aa raha he
ReplyDeleteNew ac purchase kiya hoga service center phine kro vo code btaenge unko model nmbr btana chal jaegi
DeleteH4 error problem?
ReplyDeleteH4
ReplyDeleteOF error code in voltas ac
ReplyDeletePost a Comment