VOLTAS VRF ERROR CODE

 

VOLTAS Fault Code

A1- Indoor ambient temperature sensor failure.

A2 - Temperature sensor about middle position of evaporator failure.

A3 - Indoor coil pipe inlet temperature sensor failure.

A4 - Indoor coil pipe outlet temperature sensor failure.

A5 -  Indoor water pump failure .

A6 - Failure of indoor PG fan.

H1 - HPSa fault / Fluctuation of voltage ( application to some models ) .

H5 - Refrigerant shortage protection.

HJ - Missing phase or phase sequence errors in three - phase power supply .

HF - Low oil temperature protection.     

C1 - Environment temperature sensor Tao fault.

C2 - Defrost temperature sensor Tdef fault.

C3 - Discharge temperature of inverter compressor 1 failure.

C4 - Discharge temperature of inverter compressor 2 failure.

C6 - Suction temperature of compressor failure.

C9 - Heat exchanger inlet Tcol fault.

CJ - Oil temperature Toila fault.

CC - Liquid outlet of plate heat exchanger temperature sensor fault .

CE - Gas inlet of plate heat exchanger temperature sensor fault .

CF - Gas outlet of plate heat exchanger temperature sensor fault.

J1 - The communication between ODU and ODU failed.

J2 - Communication error between outdoor and indoor unit .

J3 - The communication between PCB and INV module failure.

J4 - The communication between main PCB and DC fan motor drive module failure.

J5 - Outdoor unit parameter setting incorrect.

J7 - Outdoor unit main control PCB ERROM module failure.

A8 - Indoor unit EEPROM module failure .

A9 - The communication between indoor unit and outdoor unit failed.

AA - The communication between indoor unit and wire controller failed.

AC - Two or more indoor unit central control system address repeated.

AE -  Operation mode conflict.

AH - Two or more indoor unit refrigerant system address repeated.

AJ - Indoor unit total capacity exceeded.

JJ - Indoor unit total capacity exceeding.

E1 - The four - valve is in fault.                                                                                                                                   

E3 - DC inverter compressor 1 discharge temperature " Tda too high shutdown protection .

E4 - DC inverter compressor 2 discharge temperature " Tda " too high shutdown protection.

E9 - Drive refrigerant cooling pipe low temperature protection.

F1 - High pressure sensor " Pd  " failure.

F3 - High pressure sensor " Pd " protection .

F4 - Low pressure sensor " Ps " failure .

F6 - Low pressure sensor " Ps " protection.

F8 - Compression ratio too high protection .

F9 - Compression ratio too low protection .

FH - DC inverter discharge temperature " Tda too low shutdown protection ..

31 - IPM module protection.

32 - Compressor 1 Module hardware protection.

33 - Compressor I Module software protection .

34 - Compressor I unconnected .

35 - Compressor I phase current overload protection.

36 - Compressor 1 DC bus voltage over - voltage or under - voltage failure.

37 Compressor I temperature sensor of drive module heat fins failure.

38 - Compressor I drive module high temperature limit frequency failure.

39 - Compressor I drive module high Temp . shutdown protection .

3A - DC fan motor I drive module protection.

3H - DC fan motor I drive module start failure of Running out of step.

3C - DC fan motor 1 drive module overcurrent protection of overcurrent sensor failure .

3J - DC fan motor 1 drive module over - voltage or under - voltage protection .

3E - Compressor I input current protection.

3F - Compressor I drive module PFC protection.

41 - DC fan motor I drive module IPM alarm.

47 - Indoor unit loss failure.

49 - DC fan motor 2 drive module IPM alarm .

51- Compression2 drive module IPM protection .

52 - Compressor 2 Module hardware protection.

53 - Compressor 2 Module software protection .

54 - Compressor 2 unconnected.

55 - Compressor 2 phase current overload protection.

56 - Compressor 2 DC bus voltage over - voltage of under - voltage failure.

57 - Compressor 2 temperature sensor of drive module heat fins failure.

58 - Compressor 2 drive module high temperature limit frequency failure .

59 - Compressor 2 drive module high Temp , shutdown protection.

5A - DC fan motor 2drive module protection.

5H - DC fan motor 2 drive module start failure or a Running out of step .

5C - DC fan motor 2 drive module over current protection of over current sensor failure.

5J - DC fan motor 2 drive module over - voltage or under - voltage protection.

5E - Compressor 2 input current protection.

5F - Compressor 2 drive module PFC protection.

10 Comments

  1. How to fix AH ERROR

    ReplyDelete
  2. How to fix 33 error

    ReplyDelete
  3. 1hd ka kya matleb hota he

    ReplyDelete
  4. Voltas vxv me HJ error code AA Raha hi

    ReplyDelete
  5. 88 error aa raha he

    ReplyDelete
    Replies
    1. New ac purchase kiya hoga service center phine kro vo code btaenge unko model nmbr btana chal jaegi

      Delete
  6. H4 error problem?

    ReplyDelete
  7. OF error code in voltas ac

    ReplyDelete

Post a Comment