Daikin VRV Error code
A0 - External protection device was activated.
A1 - EEPROM failure ( indoor ).
A3 - Drain system malfunction ( indoor ).
A6 - Fan motor malfunction ( indoor ).
A7 - Swing flap motor malfunction ( indoor ).
A9 - Expansion valve malfunction ( indoor ).
AF - Drain malfunction ( indoor unit ).
AH - Filter dust chamber malfunction ( indoor ).
AJ - Capacity setting malfunction ( indoor ).
C1 - Transmission malfunction between main PCB and sub PCB ( indoor ).
C4 - Heat exchanger thermistor malfunction ( indoor ; liquid ).
C5 - Heat exchanger thermistor malfunction ( indoor ; gas ).
C9 - Suction thermistor malfunction ( indoor ).
CA - Discharge air thermistor malfunction ( indoor ).
CE - Movement detector or floor temperature sensor malfunction ( indoor ).
CJ - User interface thermistor malfunction ( indoor ).
E1 - PCB malfunction ( outdoor ).
E2 - Current leakage detector was activated ( outdoor ).
E3 - High pressure switch was activated.
E4 - Low pressure malfunction ( outdoor ).
E5 - Compressor lock detection ( outdoor ).
E7 - Fan motor malfunction ( outdoor ).
E9 - Electronic expansion valve malfunction ( outdoor ).
F3 - Discharge temperature malfunction ( outdoor ).
F4 - Abnormal suction temperature ( outdoor ).
F6 - Refrigerant overcharge detection.
H3 - High pressure switch malfunction.
H4 - Low pressure switch malfunction.
H7 - Fan motor trouble ( outdoor ).
H9 - Ambient temperature sensor malfunction ( outdoor ).
J1 - Pressure sensor malfunction.
J2 - Current sensor malfunction.
J3 - Discharge temperature sensor malfunction ( outdoor ).
J4 - Heat exchanger gas temperature sensor malfunction ( outdoor ).
J5 - Suction temperature sensor malfunction ( outdoor ).
J6 - De - icing temperature sensor malfunction ( outdoor ).
J7 - Liquid temperature sensor ( after subcool HE ) malfunction ( outdoor ).
J8 - Liquid temperature sensor ( coil ) malfunction ( outdoor ).
J9 - Gas temperature sensor ( after subcool HE ) malfunction ( outdoor ).
JA - High pressure sensor malfunction ( S1NPH ).
JC - Low pressure sensor malfunction ( S1NPL ).
L1 - INV PCB abnormal.
L4 - Fin temperature abnormal.
L5 - Inverter PCB faulty.
L8 - Compressor over current detected L9 - Compressor lock ( startup ).
LC - Transmission outdoor unit - inverter : INV transmission trouble.
P1 - INV unbalanced power supply voltage.
P2 - Autocharge operation related.
P4 - Fin thermistor malfunction.
P8 - Autocharge operation related.
P9 - Autocharge operation related.
PE - Autocharge operation related.
PJ - Capacity setting malfunction ( outdoor ).
U0 - Abnormal low pressure drop , faulty expansion valve.
U1 - Open phase.
U2 - INV voltage power shortage.
U3 - System test run not yet executed.
U4 - Faulty wiring indoor / outdoor.
U5 - Abnormal user interface - indoor communication.
U7 - Faulty wiring to Q1 / Q2.
U8 - Abnormal main - sub user interface communication.
U9 - System mismatch . Wrong type of indoor units combined . Indoor unit malfunction. .
UR - Connection malfunction over indoor units or type mismatch.
UC- Centralized address duplication.
UE - Malfunction in communication centralized control device - indoor unit.
UF - Auto address malfunction ( inconsistency ).
UH - Auto address malfunction ( inconsistency ).